Screw Pile Capacity Charts (kN)

Low Headroom    •    Limited Access Areas    •    High Water Tables    •    Tree Root Protection    •    Temporary works

Reliable Screw Pile Capacity Data
for Helical Pile Design, Engineering & Installation

Helical screw piles are a proven, high-performance solution for foundations across the UK — especially where ground conditions are challenging. Our screw pile bearing capacity charts provide quick, dependable load information for both compression and tension applications, helping engineers, contractors, and structural designers specify the correct pile size with confidence.

Whether you’re working in low-headroom environments, restricted access sites, high water tables, tree-root protection zones, or delivering temporary works, helical piles provide speed, versatility, and a clean installation process with minimal disruption.

Why Bearing Capacity Matters

Accurate load information is essential for safe, compliant and efficient foundation design.
Our screw pile load chart will help you determine:

  • Ultimate and allowable load capacities (kN)
  • Compression and tension load performance
  • Recommended pile types for specific soil conditions
  • Torque-to-capacity correlations
  • Suitable pile configurations for varying structural demands and site constraints
  • Depth requirements for various structural loads

● SQUARE SHAFT (SS) HELICAL PULLDOWN MICROPILES (HPM)

GEOTECHNICAL CAPACITIES


Soil TypeProduct FamilyAxial Compression / Tension Capacity*
“N60”- Value*
Cohesive
“N60”-Value*
Non-Cohesive
Square Shaft mm,
Micropile diameter mm
Torque
Rating Nm
Ultimate
Capacity kN
Allowable Capacity
kN with FOS 2
25 – 3525 - 30SS5-38mm,160mm 7730 Upto 508Upto 254
25 - 4025 - 35SS150-38mm,160mm9500Upto 624Upto 312
35 - 5035 -40SS175-44mm,180mm14200Upto 934Upto 467
50 - 7040 - 60SS200-51mm,180mm21,700Upto 1424Upto 712
70 - 9060 - 80SS225-57mm,180mm 28475Upto 1864Upto 932
CHART: CHANCE Helical Pile / Anchor Load Capacity, Table 7-4 FROM: CHANCE Technical Design Manual, Edition 3
* Based on torque rating and well-documented, correlations with installation torque
The HPM is a compite pile delivering end bearing and friction capacity, therefore the kN capacities detailed are dependent on the friction capacity encoured and depth of pile

HELICAL PULLDOWN MICROPILE SCHEMATIC

These charts are backed by extensive field testing and decades of engineering development — giving you reliable data for practical real-world design.

World-Leading CHANCE® Helical Piles

Ground Sun design, supply and install CHANCE® Helical Piles, globally recognised as the most tested and trusted helical foundation system in the world, CHANCE Piles are accepted as the Industry standard, and an excellent option for many foundation designs.

  • TRUST – Over 100 years of engineering expertise and global installation experience.
  • QUALITY – Manufactured under ISO 9001 certification.
  • TRACEABILITY – Pile types for specific soil conditions.
  • SERVICE – Full project support, training, and engineering guidance.
  • ADAPTABLE – Customisable pile designs for non-standard or complex projects.
  • PRODUCT RANGE – Round Shaft (RS), Square Shaft (SS), Pulldown Micropiles, instant foundations and rock anchoring systems.
  • SUSTAINABLE – Made from 98% recycled steel, removable, reusable, and exceptionally low-carbon.

Get the Right Helical Pile for Your Project

As an experienced London Piling Contractor, Ground Sun delivers precision screw pile installations across London and the South East. Whether it’s a new build, extension, or commercial structure, our screw piling solutions offer you speed, stability, and minimal environmental impact.

Get a fast no-obligation quote today and discover how helical screw piles can save you time, money, and disruption on your next project.

Need help? Speak Directly to our
Design Engineer

If you’re unsure which helical pile is right for your project or need help interpreting the screw pile capacity charts, our Design Engineer is ready to help.

Load requirements & structural considerations.

Soil conditions and feasibility.

Chart interpretation and pile selection.

Design optimisation.